Carrier 38MGR Series Service Manual page 94

Multi-zone outdoor unit ductless system, sizes 18, 24, 30, 36, 48
Table of Contents

Advertisement

DISASSEMBLY INSTRUCTIONS SIZE 30 (CONT)
4
Compressor How to remove the compressor.
94
Wires:
CN3/CN22: 4-way valve (blue-blue)
CN4/CN40: Crankcase heating cable
(black-red)
CN10/CN44: Crankcase heating
cable (black-red)
CN1:L1-IN (red)
CN2:L2-IN (black)
8) Disconnect the grounding
wire (yellow-green) after
removing the right-rear
panel.
9)
Remove the PCB board.
1) Complete the steps in the
"Panel Plate", "Fan
Assembly", and "Electrical
Parts" sections.
2) Remove the electrical
control box and the partition
plate.
3) Extract the refrigerant gas.
4) Remove the sound insulation
material and the crankcase
heating cable.
5) Remove the compressor
terminal cover, disconnect
the compressor thermo
wires, and disconnect the
compressor from the
terminal.
Specifications subject to change without notice.
CN3
CN4
CN10
CN22
CN40
CN44
CN13
CN33
CN2 CN1
38MGR-04SM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents