DIAGNOSIS AND SOLUTION (CONT)
Index 1:

DC fan motor (control chip is inside fan motor)

Power on and when the unit is in standby, measure the voltage of pin1-pin3, pin4-pin3 in fan motor connector. If the value of the voltage is not
in the range showing in the table below, the PCB needs to be replaced.
Vs
Vsp
38MGR-04SM
Fig. 60 — DC Fan Motor
NO.
COLOR
1
Red
2
---
3
Black
4
White
5
Yellow
6
Blue
Fig. 61 —Test the Voltage
Specifications subject to change without notice.
SIGNAL
VOLTAGE
Vs/Vm
200~380V
---
---
GND
0V
Vcc
13.5~16.5V
Vsp
0~6.5V
FG
13.5~16.5V
Vcc
FG