6.6.1.2 Oil Temperature
When installing the oil temperature sensor, the unbroken side of the crush washer must face the sensor
flange. The sensor is torqued finger tight plus one-half turn and safety wired in accordance with practices
defined in Section 7, Safetying, of Chapter 7, Aircraft Hardware, Control Cables and Turnbuckles, of advisory
circular AC 43.13-1B, Aircraft Inspection and Repair.
6.6.1.3 Carburetor Air Temperature
The sensor location will vary for different carburetors. Reinstall the carburetor temperature sensor as
described in Figure 6-10.
CAUTION
Fuel and air passages must remain free of contaminants during work near and around the
carburetor.