Resetting Time; Controller Features And Options - North Star PA101 Manual

Table of Contents

Advertisement

RESETTING CONTROLLER, FEATURES AND OPTIONS
To set the time if incorrect, or if the display is flashing after a power outage longer than 72 hours, reset as follows.
When power is lost, all other settings are maintained by the computer and do not require setting (see Program
Memory).
1. Press the Menu/Exit button ( ) to enter the Primary Menu. Using the up () or down
() buttons, move the cursor (>) to Set Clock and press ( ) to enter this menu.
2. Use the up () and down () buttons to set the correct time, being sure AM or PM
shows, as applicable. Up () advances the time; down () moves the time backward.
3. When the correct time shows, press Menu/Exit ( ) to set the clock and return to the
primary menu. Using the up () or down () buttons, move the cursor (>) to EXIT and
press Menu/Exit button ( ) and return to the normal operating screen.
RECHARGE: By pressing this button, the controller enters into the recharge menu.
The options are Online/Offline, Recharge Now or Recharge Tonight. Move the cursor
(>) next to selection and press Menu/Exit ( ) button. Online/Offline allows a specific
tank to be put online or taken offline. In the Recharge Now menu, you can select one
or all tanks to start an immediate recharge. Move the cursor (>) next to the specific tank and press the Menu/
Exit ( ) button. This will toggle between Service and Scheduled. In the Recharge Tonight menu, you can
schedule a recharge or cancel a recharge tonight. Move the cursor (>) next to the specific tank and press the
Menu/Exit ( ) button. This will toggle between Service or Tonight.
The following is a description of the features and options in the Primary Menu. To enter the Primary Menu, press
the Menu/Exit ( ) button. Using the up () or down () button, move the cursor to the feature or option that
you would like to change and press the Menu/Exit ( ) button to enter screen. To return to the normal operating
screen, move the cursor (>) to EXIT and press Menu/Exit button ( ).
SET SALT LEVEL: This is activated if Salt Monitor feature is set to ON. Using the up
() or down () button, set the salt level number from 0 to 10 or pressing the down ()
button past 0 will toggle Salt Monitor to OFF. This number corresponds with the
numbered decal on the brinewell that the salt level is closest to. Press the Menu/Exit
( ) button to set and return to the Primary menu. Note: This feature is not shown if
System Type is set to Filter.
SET CLOCK: Use the up () and down () buttons to set the correct time. If 12 hour
clock is set, be sure AM or PM shows, as applies. Up () advances the time; down ()
moves the time backward. By pressing and holding either the up () or down () but-
ton, the display will scroll at faster increments. Press the Menu/Exit ( ) button to set
and return to the Primary menu.
SET HARDNESS: (Softeners only) Using the up () or down () button, set the water
hardness level, from 1 to 160 grains, or 10 to 2740 PPM (parts per million). By pressing
and holding either the up () or down () button, the display will scroll at faster incre-
ments. Move the cursor (>) to EXIT and press Menu/Exit button ( ) and return to the
normal operating screen.
SET RECHARGE TIME: Using the up () or down () button, set the time when regen-
erations should start. Press the Menu/Exit ( ) button to set and return to the Primary
menu. Move the cursor (>) to EXIT and press Menu/Exit button ( ) and return to the
normal operating screen. Note: This feature is available only on parallel delayed sys-
tems and not available if System Type is set to Filter.
continued
ELECTRONIC CONTROLLER,

RESETTING TIME

FEATURES AND OPTIONS
17
EXIT
> Set Clock
Set Hardness
Set Recharge Time
Set Clock:
9:32PM
 Change
 Exit
Water
9:32 PM
Flow Rate:
2.0 GPM
 Menu
>EXIT
Online/Offline
Recharge Now
Recharge Tonight
Set Salt Level:
8
 Change
 Exit
Set Clock:
9:32PM
 Change
 Exit
Set Hardness:
25 Grains
 Change
 Exit
Set Recharge
Time:
2:00AM
 Change
 Exit

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pa071Pa131Pa191Pa321Pa251

Table of Contents