Installation Steps; Notes And Cautions - North Star PA101 Manual

Table of Contents

Advertisement

PIPING ASSEMBLY NOTES AND CAUTIONS:
BE SURE to close the main water supply valve before beginning.
S
BE SURE to plumb so hard water flows to the valve inlet fitting.
S
CAUTION: When soldering, make sub---assemblies as needed to prevent soldering heat damage to the
S
conditioner valve or bypass valve. Be sure soldered piping has cooled before connecting to the condition-
er.
Use Teflon tape or pipe joint compound on external pipe threads.
S
Lubricate o---ring seals with high quality silicone grease.
S
1.
Looking at the illustrations on page 9, and observing the notes above, run piping from the main water sup-
ply pipe to the valve inlet. Then, run return piping from the valve outlet to the supply pipe. Be sure to include
a 3---valve bypass, or use one of the optional bypass valves.
Note: When working with soldered copper, be sure to observe the caution above to avoid damage to non---me-
tallic parts.
Important: Support in and out piping in an acceptable manner, to prevent weight stress on the conditioner
valve.
2.
Move the brine tank assembly into position nearby the resin tank. Enough tubing is included to allow locating
the tank up to 10 ' away from the resin tank (Figure 6).
3a.
Connect Tubing --- Model PA071: Thread the brine tube through the hole of the brine tank sidewall. Fasten
tubing to the nozzle assembly (Figure 6) using the compression nut---ferrule, tightening securely, by hand only.
3b.
Connect Tubing --- All other models: Verify that the proper nozzle & venturi are installed in nozzle assembly.
If not, replace with correct pair.
¡ Install two elbows (in separate parts bag with the brine tank) into the top and bottom of the nozzle assem-
bly (Figure 6).
© Using tubing inserts and compression nuts, fasten lengths of tubing to the two elbows.
¢ Connect tubing from the bottom of the nozzle assembly, to the top adaptor on the front of the condition-
er valve assembly. Use a tubing insert and compression nut (tighten securely) as shown in the inset drawing.
£ Do the same to connect tubing from the top of the nozzle, to the bottom check valve fitting on the front
of the conditioner valve assembly.
continued
nozzle/venturi
nut--ferrule
brine
valve tubing
brinewell

INSTALLATION STEPS

Model
PA101, PA131
PA191, PA251 & PA321
Figure 6
hose
adaptor
grommet
overflow
drain
hose
to floor
drain
BRINE TANK
Venturi
Nozzle
Almond
White
Gray
Gray
brine return
adaptor
check
valve
pressure
nozzle
assembly
10
insert
nut
hose
adaptor
elbow (2)
grommet
overflow
drain
hose
to floor
BRINE TANK
drain
fitting

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pa071Pa131Pa191Pa321Pa251