Press the latch at one side using a slotted screw‐
driver or similar tool – and push out the plug insert
by approx. 2 mm.
Remove the plug insert.
Push the plug insert into the housing until it audibly
snaps into place.
8.6.6

Several Control Units and DRIVE-CLiQ Extension

It is possible to use several Control Units and DRIVE-CLiQ Extensions. This should be
configured if more than the maximum permissible number of S120Ms are operated on the same
line.
In this case, the shortest possible Hybrid Cable downstream of the DQE (< 10 m) should be
used for the first axis.
Manual, 06/2019, 6SL3097-5AW00-0BP1
8.6 Layout of the components
Repeat this operation for the second latch.