Honeywell VISTA-128BPEN Installation And Setup Manual page 79

Commercial burglary partitioned security system with scheduling
Table of Contents

Advertisement

FIELD
TITLE and DATA ENTRIES
Enable 5800 RF Button Global
1*57
Arm
0 = disable
1 = enable
Enable 5800 RF Button Force
1*58
Arm
0 = disable
1 = enable
Zone 5 Audio Alarm Verification
1*60
0 = disable
1 = enable
Abort Verify
1*61
0 = disable
1 = enable
Event Log Types
1*70
0 = disable
1 = enable
12/24 Hour Type Stamp Format
1*71
0 = 12-hour
1 = 24-hour
Event Log Printer On-Line Mode
1*72
0 = disable
1 = enable
Printer Baud Rate
1*73
0 = 1200
1 = 300
Relay Timeout XXX Minutes
1*74
Enter 000-127 times 2 minutes (000-254).
Relay Timeout YYY Seconds
1*75
Enter 000-127 seconds.
Access Control Relay (partition-
1*76
specific)
01-96 = relay number
00 = relay not used.
Extended Home Control Enable
1*78
0 = limited
1 = extended
Home Control Events
1*79
0 = disable
1 = enable
EXPLANATION
If enabled, the system arms/disarms in accordance with the button's user's
global arming settings.
If enabled, allows the RF button user to force a bypass of all faulted zones
when arming the system.
NOTE: When attempting to arm the system, the keypad beeps once after the
button is pressed if any faulted zones are present. The user should then
press the button again within 4 seconds to force-bypass those zones and arm
the system.
NOTE: Force Arm is not approved for ULC applications.
If enabled, zone 5 is used for 2-way audio (AAV).
Must be 0 for UL installations.
NOTE: Zone 5 cannot be used as protection zone.
If enabled and an alarm occurs on a non-fire zone, the system displays
"ALARM ABORTED", if a user enters the code + off sequence during the
Abort Window (field *88).
This field has five entries as follows: Alarm, Check, Bypass, Open/Close and
System. If enabled, the system logs those events into the event log.
NOTE: Events are also logged into the PassPoint system, if installed.
Select the type of time stamping for the event log.
If enabled, the system prints the events as they occur.
If disabled, the system prints the log only upon request.
Select the baud rate for the serial printer.
This is used for #80 Menu Mode Time-Driven event relay command numbers
"04/09" and Output Programming in the #93 Menu Mode Programming output
command "56."
This is used for #80 Menu Mode Time-Driven event relay command numbers
"05/10" and Output Programming in the #93 Menu Mode Programming
command "57."
If enabled, the assigned relay closes for 2 seconds when the user enters his
code and presses 0.
Must be 00 for UL installations.
NOTE: See SECTION 3: Installing the Control for enhanced access control
capabilities.
If extended, there are 255 commands to the home control command set. If
limited, there are 32 commands to the home control command set.
Home Control Automation is not allowed in UL installations.
This field has five entries as follows: Alarm, Trouble, Bypass, Open/Close,
and System. Select the type of events (status reports) transmitted via the
RS232 output.
Home Control Automation is not allowed in UL installations.
Section 5 – Data Field Descriptions
5-11