3 Setting up functions
3.2 Configuring measurements and measurement series

3.2.2 Equability test

Parameter description
Parameters for conducting an equability test:
Field
Name
Channel
Axis
Start point
End point
Feed
Fig. 3-10: Equability test on the operator panel
3-94
Content
Name of the measurement series
(measurements do not have a name).
Selection of the required channel. The
channel defines the possible machine axes in
the "Axis" selection list.
Selection of the possible machine axes that
can be programmed in the selected channel.
The axis position at which the first partial
movement of the measurement begins.
The axis position at which the first partial
movement of the measurement ends.
Velocity at which the axis is moved.
ePS Network Services, Function Manual (FH) - Release 12/2008
Type
INPUT
SELECTION
SELECTION
INPUT
INPUT
INPUT
© Siemens AG 2008 All Rights Reserved