Installation; Technical Specifications - Tomahawk ® 1000 - Code 12850 - Lincoln Electric Tomahawk 1000 Operator's Manual

Hide thumbs Also See for Tomahawk 1000:
Table of Contents

Advertisement

TOMAHAWK
®
1000

INSTALLATION

TECHNICAL SPECIFICATIONS -
TOmAHAwk
1000 - COdE 12850
®
INPUT VOLTAGE +/- 10%
208V/1/50/60
230V/1/50/60
208V/3/50/60
230V/3/50/60
460V/3/50/60
575V/3/50/60
RATED OUTPUT AT 40° C
DUTY CYCLE
CURRENT
100%
50%
40%
OUTPUT
CURRENT RANGE OPEN CIRCUIT VOLTAGE PILOT CURRENT
20 - 60 Amps
270 VDC
REQUIRED GAS FLOW RATE
80.0 PSI @ 275 SCFH
(5.5 Bar. @ 130 ±20% LITERS/MIN.)
REQUIRED GAS INLET PRESSURE
87.0 to 109.0 PSI
(6.0 Bar. to 7.5 Bar.)
RECOMMEND INPUT WIRE
For all plasma cutting applications
Based on U.S. National Electrical Code
Ambient Temperature 30
Input Cord
Supplied with
Machine
Input Supply Wires
STO, 600V
#10 (5.3 mm2)
INPUT - SINGLE PHASE/THREE PHASE/ 50 / 60 HERTZ
INPUT AMPERES @ RATED OUTPUT
38
25
34
23
25
16
21
13
9
6
8
5
VOLTAGE
40A
96VDC
60A
104 VDC
60A
104 VDC
20 Amps
o
C or Less
Type S, SO, ST, STO
or Extra Hard Usage Cord
AWG (IEC) Sizes
1 Ground Wire
#10 (5.3 mm2)
50% Duty Cycle
100% Duty Cycle
50% Duty Cycle
100% Duty Cycle
50% Duty Cycle
100% Duty Cycle
50% Duty Cycle
100% Duty Cycle
50% Duty Cycle
100% Duty Cycle
40% Duty Cycle
100% Duty Cycle
PHYSICAL DIMENSIONS
HEIGHT
WIDTH
15.3 in.
9.7 in.
389 mm
247 m
TEMPERATURE RANGES
OPERATING TEMPERATURE
RANGE
-10°C to +40°C
A-1
INSTALLATION
CIRCUIT BREAKER (DELAY TYPE)
40 Amps
30 Amps
15 Amps
WEIGHT
DEPTH
INCLUDING
TORCH CABLE
21.65 in.
63.9 lbs.
550 mm
29 kgs
STORAGE TEMPERATURE
RANGE
-25°C to +55°C

Advertisement

Table of Contents
loading

Table of Contents