2-5 Wiring & output circuit
Models with serial & analogue output
2
Connector PIN assignment - receiver
M12 n8 pole
Connector PIN assignment - transmitter
M12 n4 pole
For synchronization by wire please connect the red wire of receiver with white wire of
transmitter.
We recommend protecting the control unit with an external fuse, whose rated breaking current
must be 1A, even if the appliance is provided with its own internal, self-resetting fuse.
2-6
Variable
Power Supply
Earth
Ground +24 VDC 0 VDC
Type
Internal wiring
Type
Internal wiring
Safety Points
F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL
RECEIVER F3EM2
Wh
Br
Gn
Ye
Gr
Pk
RS out
Analogue
S
1
EMITTER F3EM2
Br
Wh
Bl
Bk
SYNC.
Pin
Colour
White
1
2
Brown
3
Green
4
Yellow
5
Gray
6
Pink
7
Blue
8
Red
Pin
Colour
1
Brown
2
White
3
Blue
4
Black
Bl
Rd
Signal name
Strobe input/alignment
(normally open)
+Vs
RS+ or RS TX
RS- or RS RX
Analogue +
Analogue reference
0V
Wire synch
Signal name
+Vs
Wire sync
0V
Not used