Trouble-Shooting - Robin America RGX305, RGX305D, RGX405, RGX405D, RGX505, RGX505D Service Manual

Technical data & overhaul instructions
Table of Contents

Advertisement

11. TROUBLE-SHOOTING
When the generator is in trouble, check carefully the trouble part and remedy it.
(I)
(Cause)
(Remedy)
YES
Win? checked?
Wrong
wiring
or some
leads unconnected.
1 OK
Resistance
outside
range of 5 -7.5X2
Slip ring defective
Resistance
outside
range of 5 -7.5a
Field coil short
Main coil broken
Sub coil broken
resistance
in 9-l .I
AVR
broken
Replace.
Wire correctly.
Replace
exciting
coil.
a
Replace
AVR.
Clean, replace.
Check,
replace.
Replace.
Replace
stator.
Replace
stator.
Replace
AVR.
- 59 -