RECEPTACLE
and AC PLUG
Check the current-carrying parts of the receptacles and AC plugs and their leads and plastic parts for bums.
9-7
VOLTMETERS
Apply AC voltage to a terminal and check if the voltmeter
reads normal.
9-8
DIODE STACK ASSEMBLY
--
+
e-
I-
Fig. 9-9
VOLTMETER
Fig. 9-8
Fig. 9-10
The internal circuitry
of the diode stack assembly is as
shown in Fig. 9-9. Check inter-terminal continuity
with a
tester as shown in Fig. 9-10 to see that the results are as
shown in Table 9 -8.
I
TERMINAL,
CURRENT
; TERMINAL
NOTE:
A --4-c
B Current flows from A (+I to B 1-J.
1-1
C -
D Current does not flow from C PI to D l-1.
'-I-!-
-
Check both terminals
Table 9- 8