Rotor Assembly - Robin America RGX305, RGX305D, RGX405, RGX405D, RGX505, RGX505D Service Manual

Technical data & overhaul instructions
Table of Contents

Advertisement

*RGX505,
RGX505D
l
50Hz 22OV. 23OV, 240V
yzJG-Jq
ml
l
50H.z 1 lOV, llOVI22OV.
12OVl24OV
l
60Hz 11OV. 12OV, llOVi22OV.
12OVi24OV
1 Wire color
i
BLUE
1
I
BLUE
]
0.14
52 1
9-l-2
MEASURING
INSULATION
RESISTANCE
Refer to
8-4 MEASURING
INSULATION
RESISTANCE.
ROTOR
9-2
ROTOR ASSEMBLY
9-2-l
WWDING
RESISTANCE
MEASURING
Check the resistance between the two slip rings with a test-
er. (See Fig. 9-2.)
The resistance is normal if it is anywhere from 5 ohms to
7.5 ohms.
TESTER
Fig. 9-2
9-2-2
MEASURING
INSULATION
RESISTANCE
Refer to
8-4 MEASURING
INSULATION
RESISTANCE.
9-2-3
CLEANING
SLIP RINGS
The slip ring surfaces must be uniformly bright. Slip rings
showing black spots, excessive wear, or uneven wear must
be repaired. A stained slip ring lowers generator efficiency
and output voltage. Polish the slip rings with fine sandpaper
while turning the rotor until rough spots disappear. Care
should be taken not to touch the rotor coils with the sand-
paper. (See Fig. 9-3.)
SANDPAPER
Fig. 9-3
- 37 -