Closed Circuits Thermocouple Testing (White Rodgers Mechanical) - Bradford White Defender RG130T Series Service Manual

Flammable vapor ignition resistant water heaters
Hide thumbs Also See for Defender RG130T Series:
Table of Contents

Advertisement

CLOSED CIRCUIT THERMOCOUPLE TESTING (White Rodgers Mechanical)
Step 1.
Closed circuit testing is the preferred method for testing the thermocouple. Following the lighting
instruction label on the heater, proceed to light the pilot and allow to operate for three minutes. If
the pilot will not stay lit, hold the pilot button (located on the combination thermostat/gas valve)
down during this test.
Using a multimeter capable of measuring millivolts, connect one lead using an alligator clip to the
Step 2.
copper sheath of the thermocouple. Use the second lead of the multimeter to probe the top
terminal located at the back of the combination thermostat/gas valve.
Step 3.
If meter reads 10 millivolts or higher, the thermocouple is O.K.. If reading is below
10 millivolts, replace the thermocouple.
SERVICE PROCEDURE RG-II
Thermocouple/Thermopile Testing and
Alligator clip to copper
sheath of thermocouple
15
Replacement
15