NOTE: The following procedure applies
to the Honeywell gas control ONLY.

HONEYWELL COVER REMOVAL

Step 1. Rotate the knob of the gas control to the "OFF" position.
Step 2. Turn off gas supply to the water heater.
Step 3. Disconnect the gas supply line from the gas control.
Step 4. Disconnect the piezo igniter wire.
Step 5. Remove the gas control cover screw using flat-head
screwdriver.
Gas control
cover screw
Step 6. Depress both tabs on the top of the gas control cover and pull straight out to remove.
26
SERVICE PROCEDURE RG-VI
Gas Control Testing, Disassembly, & R eplacement
(Honeywell ONLY)
Use caution to not bend or damage
valve body pins when removing or
installing the gas control cover.
Rotate knob counter-clockwise to
the "OFF" position
26
CAUTION
Valve body