NEC UNIVERGE SV8300 Command Manual page 331

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
31
Y
DATA
A
32
Tone Duration (Off time) of MFC (Forward
Signal/Backward Signal)
[8300R3.5]
NOTE:
33
Forward signal receiver start delay time
[8300R3.5]
NOTE:
34
Forward signal receiver detect Level
[8300R3.5]
NOTE:
MFC/MF-ANI TRUNK DATA
1ST DATA
MEANING
A reset by CM31 Y=A>90: 0 is required after this data setting.
A reset by CM31 Y=A>90: 0 is required after this data setting.
A reset by CM31 Y=A>90: 0 is required after this data setting.
DATA
01
20 ms.
98
1960 ms.
99
5100 ms.
NONE
100 ms.
00
0 ms.
98
24.5 ms.
99
64 ms.
NONE
0 ms.
00
Detect Level 0: 0 to -25 dBm
01
Detect Level 1: -5 to -30 dBm
02
Detect Level 2: -10 to -35 dBm
03
Detect Level 3: -15 to -40 dBm
04
Detect Level 4: -20 to -45 dBm
05
Detect Level 5: -25 to -50 dBm
06
Detect Level 6: -30 to -55 dBm
NONE
Detect Level 0: 0 to -25 dBm
3-275
: Default
2ND DATA
MEANING
Increment unit: 20 ms.
Increment unit: 0.25 ms.
Continued on next page
NWA-033623-001 Rev.8.1
JANUARY/14/2011
CM31
91ch3003.fm