Table 1: Troubleshooting (Continued)
Problem
Red LOW salt LED is
on.
Red LOW SALT light on
and green CELL light
flashing
Red CHECK SALT light
is on
Green GOOD salt light
is flashing
COLD WATER light is
red.
CELL light does not
come on.
CELL light is flashing
green.
Flow light is red.
IntelliChlor unit does
not have power.
IntelliChlor Salt Chlorine Generator Installation and User's Guide
Possible Cause
Pool water needs salt. No chlorine is being
produced.
Salt level in pool water is low and may need
inspecting.
Not enough salt in pool.
Heavy Rainfall.
Leak in pool.
Too much salt in pool. May cause damage to
pool releated equipment and surrounding
surfaces.
Water is below 52°F.
Chlorine Production set to 00%.
Insufficient water flow. Cell is plugged with
debris, pump has lost prime.
Salt level below 2600 ppm.
Check salt level
Cell has calcium build-up and requires
cleaning.
Check water chemistry and balance.
NOTE metal content should be 0 ppm.
Pump fails to provide sufficient water flow.
Closed valves.
Dirty filter.
Obstruction in the Chlorinator cell.
Fuse in Power Center is open.
No AC power to Power Center.
Transformer leads not wired correctly in Power
Center.
Corrective Action
Add salt as described on pages 13, 14.
Check salt level, add if necessary to GOOD
level. Allow 24 hours for salt to mix in water. If
CELL light is still flashing after 24 hours,
remove and inspect cell and clean if necessary.
Add salt to pool to achieve 3400 ppm.
See page 13, 14.
Dilute pool water by draining some water, then
filling with fresh water
The water temperature must be above 52°F to
produce chlorine.
Adjust CHLORINE PRODUCTION to desired
percentage.
Remove obstruction and/or clean cell. See
page 10. Prime pump if necessary.
Add salt as described on pages 13, 14,
and 15.
Add salt if necessary to maintain 3400 ppm
minimum.
Refer to Maintenance Procedure for acid
wash/cleaning. See "User Maintenance,"
on page 9.
Remove metals from water using chemical
solution.
Check for correct operation of the pump, i.e.,
loss of pump prime or clogged strainer
baskets.
Check and correct all valve alignments.
Follow filter cleaning procedures.
Remove cell for inspection. Follow cleaning
procedures. See "Electrolytic Cell Cleaning,"
on page 20.
Replace AC fuse, located at bottom of Power
Center.
Verify time clock is providing 110 VAC or 220
VAC to Power Center when active.
Verify transformer leads wired to AC source by
referring to wiring diagram decal on inside of
Power Center cover.