Siwarex Wl230 Sb-S Sa - Siemens SIWAREX WL200 Series Operating Instructions Manual

Load cell
Hide thumbs Also See for SIWAREX WL200 Series:
Table of Contents

Advertisement

Variable
Maximum tightening torque for the fixing bolts
for E
for E
for E
Cable connection
for E
for E
Output is current-calibrated
1)
9.1.10

SIWAREX WL230 SB-S SA

Table 9- 10
Variable
Type series
Designation
Construction type
Possible applications
Rated load E
Accuracy class according to OIML R60
Max. scale interval n
Min. scale interval V
for E
for E
Combined error F
Deviation F
Creep error F
30 min
Temperature coefficient
Characteristic value T
Zero signal T
Min. initial loading E
Maximum working load L
Break load L
Maximum lateral load L
SIWAREX WL200
Operating Instructions, 07/2016, A5E02199611B-03
= 100; 250; 500 kg, 1 t, 2 t
max
= 3; 5 t
max
= 10 t
max
= 100; 250; 500 kg, 1 t, 2 t
max
= 3; 5; 10 t
max
Technical data SIWAREX WL230 SB-S SA
max
LC
min
= 500 kg
max
= 1; 2; 5 t
1)
max
comb
V
cr
Kc
Ko
min
u
d
lq
9.1 Functional data
Value
75 Nm
500 Nm
750 Nm
Four-core, shielded
4 m
6 m
Value
WL230
SB-S SA
Shear beam
Platform scales,
overhead rail scales,
container weighers,
conveyor scales
500 kg
1; 2; 5 t
C3
1)
3000
E
/ 10000
max
E
/ 15000
max
± 0.02% C
n
± 0.02% C
n
± 0.02% C
n
0.017% C
/ 10 K
n
0.023% C
/ 10 K
n
0 kg
150% E
max
300% E
max
100% E
max
Technical data
55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Siwarex wl260 sp-s aaSiwarex wl260 sp-s abSiwarex wl260 sp-s aeSiwarex wl260 sp-s saSiwarex wl260 sp-s sbSiwarex wl260 sp-s sc ... Show all

Table of Contents