Technical data
9.1 Functional data
Variable
Sensor material
Degree of protection according to EN 60 529
Cable connection
Maximum tightening torque of the fixing screws
9.1.6

SIWAREX WL260 SP-S SC

Table 9- 6
Variable
Type series
Designation
Construction type
Possible applications
Rated load E
Accuracy class according to
OIML R60
Max. scale interval n
Min. scale interval V
Combined error F
Deviation F
Creep error F
30 min
Temperature coefficient
Characteristic value T
Zero signal T
Min. initial loading E
Maximum working load L
Break load L
Maximum lateral load L
Rated measuring path h
50, 100, 250, 500 kg
Recommended supply voltage
Maximum supply voltage
Rated characteristic value C
Tolerance of zero signal D
Input resistance R
for E
for E
50
Technical data SIWAREX WL260 SP-S SC
max
LC
min
comb
V
cr
Kc
Ko
min
u
d
lq
at E
n
max
Rated
o
i
10, 20, 50
max
100, 200, 300, 400, 500
max
Single-point scales, conveyor scales
10, 20, 50, 100, 200, 300,
400, 500 kg
C3
3000
E
/ 10000
max
≤ ± 0.02% C
± 0.02% C
≤ ± 0.0245 %
≤ ± 0.0100 %
≤ ± 0.0140 %
0 kg
150% E
max
300% E
max
100% E
max
=
Operating Instructions, 07/2016, A5E02199611B-03
Value
Stainless steel, mat. no. 1.4542
IP68
Six-core, shielded PU cable
6 m
10 Nm
Value
WL260
SP-S SC
Single-point load cell
10, 20, 50 kg
4000
E
1)
max
≤ ± 0.014% Cn
n
n
≤ ± 0.0184 %
≤ ± 0.0080 %
≤ ± 0.0035 %
0 kg
150% E
300% E
100% E
≤ 0.19 mm
5 to 12 V DC
18 V DC
2.0 ± 0.2 mV/V
< ± 2.0% C
n
380 ± 15 Ω
350 ± 3.5 Ω
C4
/ 40000
max
max
max
SIWAREX WL200