Variable
Maximum tightening torque of the fixing screws
for E
for E
Cable connection
Type approval to OIML for SIWAREX WL260 SP-S SA available soon
1)
9.1.5

SIWAREX WL260 SP-S SB

Table 9- 5
Variable
Type series
Designation
Construction type
Possible applications
Rated load E
Accuracy class according to OIML R60
Max. scale interval n
Min. scale interval V
Combined error F
Deviation F
Creep error F
30 min
Temperature coefficient
Characteristic value T
Zero signal T
Min. initial loading E
Maximum working load L
Break load L
Maximum lateral load L
Recommended supply voltage
Maximum supply voltage
Rated characteristic value C
Tolerance of zero signal D
Input resistance R
Output resistance R
Insulation resistance R
Rated temperature range B
Operating temperature range B
Storage temperature range B
SIWAREX WL200
Operating Instructions, 07/2016, A5E02199611B-03
= 5; 10; 20; 50; 100 kg
max
= 200 kg
max
Technical data SIWAREX WL260 SP-S SB
max
LC
min
comb
V
cr
Kc
Ko
min
u
d
lq
Rated
o
i
o
is
tn
ts
tu
9.1 Functional data
Value
14 Nm
16 Nm
Six-core, shielded
1 m
Value
WL260
SP-S SB
Single-point load cell
Single-point scales, conveyor scales
6; 12; 30; 60 kg
C3
3000
E
/ 15000
max
≤ ± 0.02% C
n
± 0.02% C
n
≤ ± 0.0245% C
n
0.0090% C
/ 10 K
n
0.0094% C
/ 10 K
n
0 kg
150% E
max
300% E
max
100% E
max
5 to 12 V DC
18 V DC
2.0 ± 0.2 mV/V
< ± 1.5% C
n
400 ± 20 Ω
350 ± 3.5 Ω
≥ 5000 MΩ at 50 V DC
- 10 to + 40 °C
- 35 to + 65 °C
- 35 to + 65 °C
Technical data
49