Hardware Setup Procedure; Quick Start Test Setup - Texas Instruments ADS54J20EVM User Manual

Table of Contents

Advertisement

www.ti.com
2.2

Hardware Setup Procedure

A typical test setup using the ADS54J20EVM and TSW14J56EVM is shown in
setup used for the quick start procedure. The rest of this section describes the hardware setup steps.
Analog Input
Low-Noise
Signal Generator
170 MHz, +15 dBm
170-MHz
Bandpass
Filter
2.2.1
TSW14J56EVM Setup
First, setup the TSW14J56EVM using the following steps:
1. Connect the ADS54J20EVM to the TSW14J56EVM using the FMC connectors.
2. Connect the included power supply cable to connector J11 (+5V IN) and the other end to a +5 VDC
±0.3 VDC 3-A power supply.
3. Connect the included mini-USB cable to the USB connector (J9).
4. turn on the power supply. Flip the power switch (SW6) to the ON position. The board should draw
around 0.5 A after power up. This will increase to around 1.7 A when loaded with firmware.
SLAU687 – May 2016
Submit Documentation Feedback
Low-Noise
Power Supply
5 VDC @ 3 A
5-VDC Power Supply Cable
BINP
AINP
ADS54J20
EVM
Figure 2. Quick Start Test Setup
Copyright © 2016, Texas Instruments Incorporated
Figure
Mini-USB Cable
USB 3.0 Cable
Power
Switch
Low-Noise
TSW14J56EVM
Power Supply
5 VDC @ 3 A
Quick Start Guide
2. This is the test
PC Running
HSDC Pro
5
ADS54J20EVM