Table 13: NIE49 Ordering Information
Product Code Number
MS-NIE49xx-x (Base features of
each NIE49)
MS-NIE4910-2
MS-NIE4920-2
1
For repair parts, add -702 after the code number.
2
Modbus RTU (RS-485) requires an RS-232/RS-485 converter. See .
3
M-Bus protocol requires the addition of an external level converter. See .
4
KNX protocol requires addition of the KNX IP gateway. See .
5
This accessory is available from Systems Integration Services - Europe and Africa.
Table 14: NIEx9 Accessories Ordering Information
Product Code Number
MS-BAT1010-0
MS-BAT1020-0
Table 15: Modbus Accessories Ordering Information
Product Code Number
1
IU-9100-8401 (Europe)
IU-9100-8404 (Europe) or
BM485-CIP (North America)
1
European market: order this accessory in AOMS from the Essen Distribution Center. North American market: order this
accessory from duTec
Table 16: M-Bus Accessories Ordering Information
Product Code Number
1
SIS-MBUSSCSL-0E
1
SIS-MBUSSCLL-0E
1
SIS-MBUSRPLL-0E
1
SIS-MBUSRPLH-0E
1
SIS-MBUSNCLL-0E
1
SIS-MBUSNCLH-0E
1
INT-DX-KAB01
1
European market: order this accessory in AOMS from the Essen Distribution Center.
NIE39/NIE49 Installation Instructions
1
Description
Each NIE49 Series model requires a 24 VAC power supply. Each model includes two
RS-232-C serial ports, one USB serial port, one RS-485 or LON port, one Ethernet port,
and an MS-BAT1020-0 Data Protection Battery. Up to two ports can be defined for third-party
integration. The other ports have to be defined in order to use standard protocols (N2,
BACnet MS/TP, or LON). Supports BACnet IP network.
Supports two third-party trunks (Modbus RTU
or one BACnet MS/TP (RS-485) trunk. The number of supported devices on the third-party
trunk depends on the protocol. For the N2 Bus or BACnet MS/TP trunk, up to 100 devices
are supported.
Supports two third-party trunks (Modbus RTU
trunk. The number of supported devices on the third-party trunk depends on the protocol.
For the L
W
ON
ORKS
Description
Replacement data protection battery for NAE55 and NIE59. Rechargeable gel cell battery:
12 V, 1.2 Ah, with a typical life of 3 to 5 years at 21°C (70°F)
Replacement data protection battery for NAE35, NIE39, NAE45, NIE45, NIE49, NCE25, or
NIE29. Rechargeable NiMH 3.6 VDC, 500 mAh battery with a typical life of 5 to 7 years at
21°C (70°F). (Higher operating temperatures reduce battery life.)
Description
RS232-to-RS485 converter, 230 VAC
RS232-to-RS485 converter, 24 VAC
1
(http://www.interfaceconverter.com
Description
RS232-to-M-Bus level converter for up to 6 unit loads; 24 VAC/VDC
RS232-to-M-Bus level converter for up to 100 unit loads; 24 VAC/VDC
RS232-to-M-Bus level repeater for up to 100 unit loads; 24 VAC/VDC
RS232-to-M-Bus level repeater for up to 100 unit loads; 230 VAC
IP-to-M-Bus level converter for up to 100 unit loads; 24 VAC/VDC
IP-to-M-Bus level converter for up to 100 unit loads; 230 VAC
Optional connection cable SUB-D to RJ-12 for use with SIS-MBUSSCLL-0E
trunk, up to 127 devices are supported.
or 1-800-248-1632), specify vendor #290904.
2
3
or TCP, M-Bus
, or KNX
2
3
4
or TCP, M-Bus
, or KNX
4
) and one N2 Bus
) and one L
W
ON
ORKS
19