Pll F & Lpf F Fine Adjustment (Vc-280 Board) - Sony DCR-TRV16 Service Manual

Digital video camera recorder
Table of Contents

Advertisement

5. PLL f
& LPF f
Fine Adjustment (VC-280 Board)
0
0
Mode
VTR stop
Signal
Arbitrary
Measurement Point
Display data of page: 3, address: 02, 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
1F, 20, 22, 29
Specified Value
Data of page: 3, address: 02 is "00".
Data of page: 3, address: 03 is "00".
Note1: The data of page: 0, address: 10 must be "00".
Adjusting method:
Order Page Address Data
1
0
01
01
2
3
01
30
3
3
02
4
3
03
5
0
01
00
Note2: If it isn't satisfied, there are errors.
Note3: If the data of page: 3, address: 03 is other than "00", there are
errors. For the error contents, see the following table. (For the bit
values, refer to "5-4. SERVICE MODE", "4-3. 3. Bit value
discrimination".)
Bit value of page: 3,
address: 03
bit 2 = 1 or bit 3 = 1
PLL f
bit 4 = 1 or bit 5 = 1
PLL f
bit 6 = 1
LPF f
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
Procedure
Set the data.
Set the data, and press PAUSE
button.
Check that the data changes to
"00" with in 5 sec. (Note2)
Check that the data is "00".
(Note3)
Set the data.
Error contents
fine adjustment is defective
0
adjustment is defective
0
is defective
0
5-47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-trv16eDcr-trv18Dcr-trv18eDcr-trv118eDcr-trv116e

Table of Contents