Installation

WD600 is shipped from the factory as three units in a heavy-duty shipping container. The
container is packed to separate each item and to provide protection during shipment.
Each item should be inspected as it is removed from the container.
Notes:
Be sure the conveyor design meets the installation requirements for the
WD600.
Adjust conveyor stringers to be rigid, straight, parallel to, and square, with
the belt line in the area of the scale installation.
Adjust pulleys to ensure that the conveyor belt tracks straight and centrally
from the head to the tail pulley.
To limit the weight and dimensions of the weighbridge on the scale, Siemens builds the
weighbridge to definite specifications as part of the scale. If a substitute or a
replacement is required, please contact Siemens. Substituting or replacing this
weighbridge with a non-specific weighbridge could result in damage to the scale due to
overloading or improper fit.
To avoid potential scale installation problems, please compare the site conditions with
WD600 installation drawings available at www.siemens.com/processautomation.
If you have any questions, please contact your Siemens representative.

Welding

WARNING:
Ensure that no welding current can flow through the belt scale. Welding currents
passing through the scale can functionally damage the load cells.
Page 6
Use extreme care when arc welding in the area of the belt scale.