DIP Switch 8 - Single Phase 3-wire: See Figure 12. Used for
setting up the proper mode for single phase operation, relevant
only when DIP switch 2 is set for single phase operation. The
default setting is for single phase 3-wire motors disabled,
when DIP switch 8 is OFF (down). To enable 3-wire single phase
motors, DIP switch 8 should be ON (up).
DIP Switch 9 – Flow Switch Dry Well Protection: See Figure 13.
When combined with an optional flow switch, the Pentair Pentek
Solar Drive offers dry well protection by setting DIP switch 9
ON (up). The Flow Switch needs to be installed in-line with the
pipe (ask your dealer for Flow Switch availability). The principle
of operation is simple. As soon as the pump starts and water
starts flowing through the pipe, the magnetic Flow Switch turns
ON, which indicates to the Pentair Pentek Solar Drive that there
is water in the well. If there is no water, the Flow Switch will
indicate a dry well condition, and the Pentair Pentek Solar Drive
will turn the pump off. There is a time delay from the start of
the pump for the Flow Switch signal to activate, which allows
time for water to flow from deep wells. See DIP Switch 10 for
time delay settings.
DIP Switch 10 – Flow Switch Time Delay: See Figure 14.
Used to define the time delay for Flow Switch sensing.
When DIP switch 10 is OFF (down) (default) the delay time is
15 seconds, while if it is ON (up), the delay time is 30 seconds.
A 15 second setting is used for more shallow wells
(less than 300ft), while 30 seconds is used for deeper wells
(deeper than 300ft).
12
SOLAR DRIVE DIP SWITCH SETTINGS
*
Phase
PNR Motor
3
P43B0010A3-C
3
P43B0015A3-C
3
P43B0020A3-C
3
P43B0030A3-C
1-3W
P43B0007A2-01
1-3W
P43B0010A2-01
1-3W
P43B0015A2-01
1-3W
P43B0020A2-C
Figure 11: Over-current Protection
DIP Switches
DIP 6
DIP 7
UP
UP
UP
DOWN
DOWN
UP
DOWN
DOWN
UP
UP
UP
DOWN
DOWN
UP
DOWN
DOWN
1 Phase, 3-Wire Enabled
1 Phase, 3-Wire Disabled
3-Wire Single Phase Option
6 and 7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
6
7
1
2 3 4 5 6 7 8 9 10 11 12
Figure 12:
Dry Well
1
2 3 4 5 6 7 8 9 10 11 12
No Dry Well
Figure 13: Dry Well Indicator
Using Magnetic Switch
30 Seconds
1
2 3 4 5 6 7 8 9 10 11 12
15 Seconds
Figure 14: Time Delay
P1062 (06/06/19)

Advertisement

Table of Contents
loading

Table of Contents