Dometic Blizzard NXT H541815A Installation Instructions Manual page 13

Roof top unit (quiet zone ducted application)
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS
FIG. 22
Use Tip Of Pliers To Hold Wire In Place
While Hand Bending Wire At 90°
FIG. 23
FIG. 24
Trim Ground Wire To Length Of Outer Wires
6. Hold the clear strain relief cover with the bottom
facing upward. See (FIG. 25).
Load Cable into Strain Relief
FIG. 25
Roll Cable Sheath Into
Integral Strain Relief
Strain
Relief
Fingers
Strain Relief Cover
(Bottom Facing Upward)
7. Lay wire into locator slots, making sure the black
wire is placed into the polarization slot. See
(FIG. 25).
Repeat With
Other Wire
Wire Locator
Slots
Position Black Wire
Into Locator Slot
8. Press the cable sheath into the integral strain
relief slot. See (FIG. 25). Trimming of ground
wire and possibly others will be necessary.
Wires must not extend beyond the locators. See
(FIG. 26).
FIG. 26
Hinge
Posts
Strain Relief Cover
9. While holding the strain relief cover, position
the housing's hinge posts into the hinge slots
and press down until both lock into place. See
(FIG. 26).
10. Close the strain relief cover and housing by
hand. Squeeze the top and bottom closed with
tongue and groove pliers. See (FIG. 27). Pliers
must be a minimum of 10" long. Squeeze firmly
on both sides, squarely across the connector
between ribs A and B to ensure wires seat com-
pletely into slots.
Attaching Housing Assembly To Strain
FIG. 27
Relief Cover With Tongue And Groove
Pliers, Squeeze Squarely & firmly
Between Ribs A & B
Strain Relief Cover
Locking
Latch
Rib A
Locking
Ramp
13
Housing Assembly
Hinge
Slots
Wires Trimmed And
Correctly Located
In Locator Stops
10" Minimum
Rib B
Housing Assembly