Terminal Description - JRC JSS-2150 Installation Manual

150w mf/hf radio equipment
Hide thumbs Also See for JSS-2150:
Table of Contents

Advertisement

INSTALLATIONS
2.2.4.4

Terminal description

TB1 - TB2 (CONTROLLER)
No.
Name
1
GND
2
NC
3
NC
4
DISP_LINE+
5
DISP_LINE-
6
DISP_KEY
7
SYS_RST
8
RS-485-A
9
RS-485-B
10
DISP_PWR
11
DISP_PWR
12
GND
13
GND
14
GND
TB11 - TB12 (EXTENSION 1) *Transceiver terminal
No.
Name
1
GND
2
NC
3
NC
4
DISP_LINE+
5
DISP_LINE-
6
DISP_KEY
7
SYS_RST
8
RS-485-A
9
RS-485-B
10
DISP_PWR
11
DISP_PWR
12
GND
13
GND
14
GND
TB21 - TB22 (EXTENSION 2) *Expansion controller terminal
No.
Name
1
GND
2
NC
3
NC
4
DISP_LINE+
5
DISP_LINE-
6
DISP_KEY
7
SYS_RST
8
RS-485-A
9
RS-485-B
10
DISP_PWR
11
DISP_PWR
12
GND
13
GND
14
GND
2-34
Ground for shielded connections
(Not used)
600 Ω equalized, 0 dBm
AF receiver signal
PTT/KEY line
System reset line
Interface for RS-485 communication (57.6 kbps)
24 VDC, maximum 3 A,
MH/HF controller NCM-2150 dedicated power supply
Ground
Ground for shielded connections
Ground for shielded connections
(Not used)
600 Ω equalized, 0 dBm
AF receiver signal
PTT/KEY line
System reset line
Interface for RS-485 communication (57.6 kbps)
24 VDC, maximum 3 A,
MH/HF controller NCM-2150 dedicated power supply
Ground
Ground for shielded connections
Ground for shielded connections
(Not used)
600 Ω equalized, 0 dBm
AF receiver signal
PTT/KEY line
System reset line
Interface for RS-485 communication (57.6 kbps)
24 VDC, maximum 3 A,
MH/HF controller NCM-2150 dedicated power supply
Ground
Ground for shielded connections
Description
Description
Description
Connection
point
NCM-2150
MF/HF
controller
(No. 1)
Connection
point
CQD-2415
terminal unit
Connection
point
NCM-2150
MF/HF
controller
(No. 2)

Hide quick links: