Intel® Raid Module Rmsp3Ad160F Electrical, Thermal And Atmospheric Requirements; Intel® Raid Module Rmsp3Ad160F Power Consumption - Intel RMSP3AD16OF Hardware User's Manual

Table of Contents

Advertisement

Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
3.1.2
Intel® RAID Module RMSP3AD160F Electrical, Thermal and Atmospheric Requirements
The Intel® RAID Module RMSP3AD160F has electrical, thermal and atmospheric requirements in order to
work properly, if those requirements are not met (operating and non-operating) the functioning of the
module cannot be guaranteed.
List of operating conditions for the Intel® RAID module RMSP3AD160F:
Power Supply voltage at the 12V rail (from PCI edge connector): 12V ± 8 percent.
Power Supply voltage at the 3.3V rail (from PCI edge connector): 13.3V ± 9 percent.
Relative humidity range is 20 percent to 80 percent non-condensing
Temperature range: 10 °C to +55 °C (with or without the RMFBU module attached)
Minimum air flow 200 LFM
List of non-operating conditions (while in storage or in transit) for the Intel® RAID module
RMSP3AD160F:
Relative humidity range is 5 percent to 90 percent non-condensing.
Temperature range: –40°C to +70°C without battery backup unit
Temperature range: 0°C to +45°C with battery backup unit
3.1.3
Intel® RAID module RMSP3AD160F Power Consumption
The following table describes the power consumption of the Intel® RAID module RMSP3AD160F
under typical and worst case scenarios:
Power Rail
3.3V
+ 12
3.3V Auxiliary
Total Power
Typical
1.33W
9.21W
0.03W
10.57W
Maximum
1.33W
9.82W
0.03W
11.18W
RMFBU Learn
6W
6W
20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rmsp3hdo80eRmsp3cd080f

Table of Contents