Fault Tolerance Features; Array Performance Features; Table 3. Fault-Tolerant Features; Table 4. Array Performance Features - Intel RMSP3AD16OF Hardware User's Manual

Table of Contents

Advertisement

Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
2.7

Fault Tolerance Features

The next table describes the Fault-tolerant features of the Intel® Tri-Mode RAID modules
Support for SMART
Drive failure detection
Drive rebuild using hot spares
Parity generation and checking
1
The Self-Monitoring Analysis and Reporting Technology (SMART) detects up to 70 percent of all
predictable drive failures. In addition, SMART monitors the internal performance of all motors,
heads, and drive electronics.
2.8

Array Performance Features

The next table describes the Array performance features of the Intel® Tri-Mode RAID modules
Specification
PCI Express host data transfer
Drive data transfer rate
Maximum scatter/gather I/O
Maximum size of I/O requests
Maximum queue tags per drive
Strip sizes
Queue Depth (SAS/SATA)

Table 3. Fault-tolerant features

Specification
1

Table 4. Array performance features

RMSP3AD160F
8GT/s per lane
Up to 12Gb/s per PHY (SAS)
Up to 6 per port (SATA)
Up to 8Gb/s per lane (NVMe)
80 elements
6.4 MB in 64-KB strips
As many as the drive can
accept
64 KB, 128 KB, 256 KB, 512 KB,
or 1 MB
4096
RMSP3AD160F
RMSP3CD080E RMSP3HD160F
Yes
Yes
Automatic
Automatic
Automatic
Automatic
Yes
Yes
RMSP3CD080E
8GT/s per lane
Up to 12Gb/s per PHY (SAS)
Up to 6 per port (SATA)
Up to 8Gb/s per lane (NVMe)
80 elements
6.4 MB in 64-KB strips
As many as the drive can
accept
64 KB, 128 KB, 256 KB, 512 KB,
or 1 MB
4096
Yes
Automatic
Automatic
Yes
RMSP3HD160F
8GT/s per lane
Up to 12Gb/s per PHY (SAS)
Up to 6 per port (SATA)
Up to 8Gb/s per lane (NVMe)
60 elements
6.4 MB in 64-KB strips
As many as the drive can
accept
64K
1517
14