Brightness; Environmental Requirements; Temperature Ranges; Humidity - Acer S230HL Service Manual

Hide thumbs Also See for S230HL:
Table of Contents

Advertisement

1.5.6 Brightness:

The brightness is determined by using a photometer (CA-210) to measure luminance on the center
of
screen after at least 30 minutes warm up. It shall be test at 1920x1080@60Hz mode and the
brightness and contrast OSD setting for 100%. The values specified are at an approximate distance
50 cm from the LCD surface and at 0 viewing angle. The full screen white center luminance at User
mode color temperature shall be 250 cd/m² typ. And > 200 cd/m² min. Full screen black pattern
luminance at center should be < 1cd/m².

1.6 Environmental Requirements:

1.6.1 Temperature Ranges:

Operating Temperature:
to 35°C
Shipping
Temperature: -25°C to 60°C
Storage Temperature: -25°C
to 60°C

1.6.2 Humidity:

Operating (non-condensing):
20% to 80% Shipping (non-
condensing): 10% to 90%
Storage (non-condensing): 10%
to 90%
1.7 Mechanical and Packing:
H e i g h t (i n c l u d i n g s ta n d )
D e p th (i n c l u d i n g s ta n d )
P a c k D i m e n s i o n s (H x W x L )
P a c k a g e d W e i g h t
U n p a c k e d U n i t W e i g h t
4 0 " c o n ta i n e r l o a d i n g , p a l l e ti z e d
M a x i m u m S ta c k i n g H e i g h t
Dimension(cm):
1. Product Specification
5°C
W i d th
S230HL
383.7 m m , 333.2 m m (w i th o u t s ta n d )
167.6 m m , 32.0m m (w i th o u t s ta n d )
548.2m m
600 (L )x 397 (W )x 115 (H )m m
3 .6 k g
2.4 k g
1890 u n i ts
5 l a y e rs , 2118 m m
ACER S230HL
16
Go to contents page

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents