8. HDD FULL ALERT: Press《ENTER》button to setup "ON" or "OFF", whether
to trigger the alarm when hard disk is full (this setup is only active when the
system is under record status).
9. BUZZER TIME: Press《ENTER》button to setup the buzzer time to continuous
(CONT), and press any button to release this setup.
10. RELAY OUT TIME: Press《ENTER》button to setup the relay out time to
continuous (CONT), and press any button to release this setup.

8.5.1 SENSOR TYPE:

1. Cursor (>) position indicates the current selected position.
2. Press 《 ←》 and 《 →》 button to move the cursor to the desired item (CH1~CH4).
3. Press《ENTER》button to make changes.
4. Press《MENU》button to exit "SENSOR SETUP" selection.
5. CHANNEL-1: Press 《 ENTER》 button to setup "NO" (Normal Open) or "NC"
(Normal Close).
6. CHANNEL-2 ~ CHANNEL-4: Please follow the setup shown above (CHANNEL-1).
SENSOR SETUP
> CHANNEL-1
CHANNEL-2
CHANNEL-3
CHANNEL-4
PRESS (< >), THEN (ENTER)
PRESS (MENU) TO EXIT
NOT INSTALLED
NOT INSTALLED
NOT INSTALLED
NOT INSTALLED