Detailed Description
2.2 Functions
REFRESH suppression
MD10131 $MN_SUPPRESS_SCREEN_REFRESH (screen refresh in case of overload)
Default setting for screen-refresh strategy with high NC utilization:
• Value 0: Refresh of current values is suppressed in all channels.
• Value 1: Refresh of current values is suppressed in time-critical channels.
• Value 2: Refresh of current values is never suppressed.
2.2.2

Settings for involute interpolation

Introduction
The involute of the circle is a curve traced out from the end point on a "piece of string"
unwinding from the curve. Involute interpolation allows trajectories along an involute.
Fig. 2-6
2-24
Involute (unwound from base circle)
Φ
Φ
Various NC/PLC Interface Signals and Functions (A2)