Wiring
If local codes permit, the water heater may
be connected to electric service with the
power cord provided (DO NOT use an
extension cord). A grounding receptacle is
required.
If local codes do not permit the use of
cord connections, a 120 V, 50/60 Hz
power supply, with suitable disconnecting
means, must be connected to the black and
white leads in the heater control enclosure.
CONNECTOR DIAGRAM
SCHÉMA DES CONNEXIONS
120 VAC PLUG FOR POWERVENT
BLOWER ASSEMBLY
H
G
PRISE DE 120 VCA POUR
N
L'ENSEMBLE DE
SOUFFLEUR D'ÉVENT MÉCHANIQUE
TEMPERATURE
SWITCH NC
BLOWER
CHANGEMENT DE
SOUFFLEUR
TEMPÉRATURE
MOT
SCREW
POWER
GND VIS
VENT BLOWER
DE MISE
ASSEMBLY
À LA TERRE
ENSEMBLE DU
SOUFFLEUR
D'ÉVENT
MÉCANIQUE
FLAMMABLE
VAPOR SENSOR
DÉTECTEUR DE
VAPEUR
INFLAMMABLE
FV
W
1
BK
W
2
BK
3
4
W
J2
BL
1
1
2
2
N/C
R
3
3
R
4
4
Y
5
5
W
6
6
WIRE HARNESS THAT RUNS FROM BLOWER ASSEMBLY
GND
TO WIPER CONTROL GAS VALVE
FAISCEAU DE CÂBLAGE ENTRE L'ENSEMBLE DU
SOUFFLEUR ET LA INTELLI-VENT DE LA SOUPAPE DE
G
CONTRÔLE DU GAZ
ANY REPLACEMENT IGNITOR CABLE MUST BE RATED AT 250º C
TOUT CÂBLE D'ALLUMAGE DE REMPLACEMENT DOIT ÊTRE
ÉTALONNÉ Á 250º C
CAUTION! Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation. VERIFY PROPER OPERATION AFTER SERVICING!
ON/OFF SWITCH
CONTACTEUR
MARCHE/ARRÉT
BK
G
W
VAC
VAC
SW NO
SW NC
CONTACTEUR À
DÉPRESSION
W BK R Y BL G
1 2 3 4 5 6
6 PIN CONNECTOR
CONNECTEUR À
1 2 3 4 5 6
6 BROCHES
W R R Y BL G
IGNITER AND
FLAME SENSOR
ALLUMEUR ET
CAPTEUR DE
FLAMME
The maximum current draw is less than
5.0 amps.
The water heater must be electrically
grounded in accordance with local codes,
or, in the absence of local codes, in accor-
dance with latest edition of the National
Electric Code ANSI/NFPA No. 70. Refer
to the figures below for water heater inter-
nal wiring.
H
SCHEMATIC DIAGRAM
SCHÉMA DE CABLÂGE
120 VAC
ON/OFF
SWITCH
CONTACTEUR
MARCHE/ARRÉT
W
1
2
BK
BK
3
W
4
BL
1
2
N/C
TEMPERATURE
R
SWITCH NC
3
CHANGEMENT DE
TEMPÉRATURE
R
4
Y
5
MOT
W
6
BK = BLACK/NOIR
BL = BLUE/BLEU
G = GREEN/VERT
R = RED/ROUGE
W = WHITE/BLANC
Y = YELLOW/JAUNE
NOTE: IF ANY OF THE ORIGINAL WIRE SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE REPLACED WITH A 18 GA, 600 V,
105º C WIRE.
REMARQUE: SI UNE PARTIE QUELCONQUE DU CÂBLAGE ORIGINAL
H
FOURNI AVEC L'APPAREIL DOIT ÊTRE REMPLACÉE, ELLE DOIT ÊTRE
REMPLACÉE AVEC UN FIL DE CALIBRE 18, 600 VCA, 105º C.
N
IGNITER
ALLUMEUR
W
FLAMMABLE VAPOR SENSOR
DÉTECTEUR DE VAPEUR INFLAMMABLE
FLAME SENSOR
CAPTEUR DE FLAMME
VAC
VAC
SW NO
SW NC
CONTACTEUR
À DÉPRESSION
BLOWER
SOUFFLEUR
GND
N