5. Assembly, set-up and installation

5.1 Hazard warnings

!
If any impurities get into the sprinkler, it is possible that the sprinkler could be destroyed
and that installers could be injured. Flush out the line thoroughly before connecting the
water supply.
!
Any unexpected emergence of a jet of water can lead to serious injury.
Make sure that the installation has been fully completed before turning on the water supply.

5.2 Installation instructions

The thread connection on the pop-up sprinkler is 2" NPT.
For the thread seal, use hemp and sealing compound, e.g. Fermit Spezial.
The pop-up sprinkler should be fitted in accordance with the 'TS170 pop-up sprinkler installation
diagram' (see next page). In order to avoid any load pressure on the main line, you should definitely
use a flexible connection.
Providing a drainage pit directly connected to the drainage, as shown in the installation diagram, is
very much recommended.
For screwing in the connection joint the housing or housing edge of the pop-up sprinkler can be
firmly held or clamped.