Recommended Processes; Additional Safety Precautions - Lincoln Electric Wire Feed Module 12207 Operator's Manual

Table of Contents

Advertisement

WIRE FEED MODULE™
DESIGN FEATURES
• Easy access to the controls located on the welder
control panel.
• Greatly enhanced welding arc performance. Now a
wider range of wire electrodes and processes are
supported by this device.
• Improved arc starting characteristics.
• Low spatter MIG welding with CO
• Built into the WFM is a power contactor that pro-
vides a "COLD" electrode when the gun trigger is
released.
• Simplified field installation process. All control wiring
connections between the welder, the control panel,
and the WFM are easily made with in-line plug type
connections.
• Includes thermostatic protection to protect the
welder from over current and over temperature.
RECOMMENDED WIRE FEEDERS AND ACCESSORIES
The WFM is designed to work with the complete
family of LN-7, LN-25, and LN-23P wire feeders.
Please refer to the connection diagram in the back of
this manual for details.

ADDITIONAL SAFETY PRECAUTIONS

The output terminals are energized when the
engine is running. The CV output will be de-ener-
gized only if WFM mode switch is in remote posi-
tion.
-------------------------------------------------------------------------
WIRE FEED MODULE OPERATION
OUTPUT
For constant voltage welding, place the CC/CV mode switch in the
CV position. Connect the wire feeder to the CV negative output
terminal and connect the work to the positive standard output ter-
minal. For electrode positive, reverse the output leads. The nega-
tive standard output terminal is not used for CV welding of either
polarity. Refer to diagrams section to determine the correct con-
nection to the remote control receptacle.
Gas.
2
WARNING
When the WFM is in the "CV" mode, the maximum auxiliary power
will be reduced by 25%. To obtain maximum auxiliary output,
place the CC/CV switch in the CC position.
If the current rating of the welder is exceeded, a thermostat will
reduce the output voltage to approximately 5 volts. The thermo-
stat will reset automatically as the machine cools. If the thermo-
stat trips, lower the wire feed speed and output voltage or reduce
Duty Cycle.
CONTROLS
The output voltage is set with the voltage control dial mounted on
the control panel. Set the "Current Range Selector" to the "190-
120" position for optimum welding characteristics. Changing the
"Current Range Selector" affects arc characteristics. Setting the
"Current Range Selector" one position to the right of the "190-
120" position will give a softer arc. If this switch is placed one
position to the left from the "190-120" set point, the machine will
produce a crisp arc characteristic. The setting of the "Fine
Current Adjustment" has no effect on the operation in "CV" mode.
For Coarse Current Control on the SAE-300 see operator manual.

RECOMMENDED PROCESSES

Refer to latest Lincoln Bulletins on (Gas Metal Arc Welding)
and (Innershield Welding) with the following electrodes:
.030"
Super Arc L-50, 56 with C-25 or CO
.035"
Super Arc L-50, 56 with C-25 or CO
.045"
Super Arc L-50, 56 with C-25 or CO
.068"
NR-203MP
5/64"
NR-203MP
5/64"
NR-207
5/64"
NR-203Nil%
B-1
OPERATION
Gas
2
Gas
2
Gas
2