WIRE FEED MODULE™
4. Remove 2 screws from brush wraparound cover.
Loosen and rotate the wraparound cover until neg-
ative brushholder is exposed. (Large flat head
screwdriver and pliers).
5. The negative brushholder is in the 11:00 O'clock
position looking at the control panel end of the gen-
erator. Remove negative brushholder 5/16" bolt.
(1/2" Socket, ratchet, and small extension.)
6. Position Wire Feed Module control box next to the
right side of the machine (as shown).
7. Feed power cable assembly through the rectangu-
lar window on the bottom of the generator.
8. Connect power cable/thermostat assembly and the
existing cables to the negative brushholder using
the .75" long 5/16" hex head cap screw, (provided
in the mounting hardware packet). Make certain
the thermostat assembly does not touch the brush-
holder spring and the cable is clear of any moving
parts. Make certain the thermostat is assembled
under the cable connections. (1/2" socket, ratchet,
small extension).
9. Reposition the brush wraparound cover and tight-
en with the hardware removed in step 5. Keep the
tightening flanges below the 3:00 O'clock position.
(Large flat head screwdriver and pliers.)