Installation Requirements; Tools And Parts; Location Requirements - Jenn-Air JBRFR24IGX Use And Care Manual And Installation Instructions

Under counter refrigerator
Hide thumbs Also See for JBRFR24IGX:
Table of Contents

Advertisement

Available languages

Available languages

TOOLS AND PARTS

Gather the required tools and parts before starting
installation
TOOLS AND PARTS NEEDED:
 Phillips screwdriver
 Custom Overlay Door Panel — Refer " Custom Overlay
Panel Preparation."
 Custom handle and mounting hardware (optional)
PARTS SUPPLIED:
 M4 x 30 flathead screws (8)

LOCATION REQUIREMENTS

WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from refrigerator.
Failure to do so can result in death, explosion, or fire.
IMPORTANT: This appliances is intended to be used in
household and similar applications such as:
 Staff kitchen areas in shops, office and other working
environments;
 Farm houses and by clients in hotels, motels and
other residential type environments;
 Bed and breakfast type environments;
 Catering and similar non-retail applications.
NOTES:
 For the refrigerator to be flush with the front of the
base cabinets, remove any baseboards or moldings
from the rear of the opening. Refer "Product
Dimensions" and later in this section, "Opening
Dimensions."
 It is recommended that you do not install the
refrigerator near an oven, radiator, or other heat
source.
 Do not install in a location where the temperature will
fall below 55°F (13°C). For best performance, do not
install the refrigerator behind a cabinet door or block
the base grille.
OPENING DIMENSIONS
 Height dimensions are shown with the leveling legs
extended to the minimum height.
NOTE: When leveling legs are fully extended, add 5/8"
(15 mm) to the height dimensions. Refer "Product
Dimensions."
 If the floor of the opening is not level with the kitchen
floor, shim the opening to make it level with the
kitchen floor.

INSTALLATION REQUIREMENTS

C
B
Opening and utility location dimensions
Opening width - A
Opening depth - B
Opening height - C
Dimension - D
Dimension - E
Dimension - F
Dimension - G
Dimension - H
Dimension - I
For flush installation, the power outlet can be installed in
adjacent cabinetry with a cutout on the power cord side
for routing of the power cord.
The power outlet can also be recessed on the back
wall behind the unit as per recommended receptacle
locations in the above illustration.
G
I
F
G
H
E
F
D
A
24" (60.96 cm) min.
24" (60.96 cm) min.
341/2" (87.6 cm) min.
35" (88.9 cm) max.
121/16" (30.64 cm)
213/4" (55.16 cm)
13/4" (4.44 cm)
3" (7.55 cm)
41/2" (11.37 cm)
91/4" (23.47 cm)
Recessed
receptacle
locations
Utility
opening