7.5
Drain/Cleaning Cycle Parameters
Sym.
Parameter Description
Initial Drain Phase Duration
Final Drain Phase Duration
Drain without cleaning cycle
Number of wash cycles possible between one drain cycle and the
next
Indicates the maximum permissible delay between drain cycle
start and the reaching of a tank level below the work level. If the
set delay is exceeded, alarm B1 occurs.
8 OTHER PARAMETERS
8.1
Dishwashing Parameters
Sym.
Parameter Description
Initial Pause before start washing (for ALL cycles)
Delay for the 2
Active a drain phase at the end of washing phase.
Duration of pause after rinse cycle (valid for dishwashers with
door/hood lock device) [See par. 9.2 MEDICAL LINE DISH-
WASHER WITH DOOR/HOOD LOCK DEVICE].
Celsius/Fahrenheit selection
0 = Celsius
1 = Fahrenheit
Rinse Temperature Display.
Enable rinse temperature probe (if installed).
0 = during rinse phase the display shows boiler temperature;
1 = during rinse phase the display shows rinse temperature;
Pulse Per Litre.
This parameter must be settled in according to flow meter
installed [present up to software version 3.12].
Number of wash cycles performable without detergent (only for
dishwashers with external detergent level sensor – par. 9.3
DETERGENT AND RINSE AID LEVEL SENSORS ACTIVATION)
[
Enable mode Thermal Label: if set to 1 it enables the mode and
disables the "endless cycle" button
Boiler temperature in mode Thermal Label.
Tank temperature in mode Thermal Label.
Tank temperature hysteresis in mode Thermal Label.
Pressure sensor threshold 1 [present up to software version 2.11].
Pressure sensor histeresis 1 [present up to software version 2.11].
Pressure sensor threshold 2 [present up to software version 2.11].
Pressure sensor histeresis 2 [present up to software version 2.11].
Note:
,
doesn't correspond to a physical quantity.
DOC. NO. 5956.65J.00
EFS - Dishwashing Systems Platform
Electrolux Professional
nd
wash pump (PW only)
]
,
,
parameters emulates a two levels pressure switch, keep in mind that value
Unit
Min
Max
[s]
0
240
[s]
0
240
-
0
1
[wash
0
200
cycles]
[s] x 10
0
100
Factory
Unit
Min
Max
Default
[s]
0
10
[s]
0
10
[s]
0
40
[s]
0
60
-
0
1
-
0
1
[p/l]
0
255
-
0
5
-
0
1
[°C]
45
97
[°C]
40
90
[°C]
0
30
-
0
255
-
0
255
-
0
255
-
0
255
Factory
Default
40
80
0
0
18
0
3
0
0
0
0
0
5
0
86
75
2
140
50
140
50
P. 16 / 174