6 TEMPERATURE SETTING
In this paragraph is explained how to change temperature thresholds and all parameters related to boiler and
tank
.
6.1 Factory Parameters
Sym.
Parameter Description
Boiler Temperature: THRESHOLD.
When boiler temperature reaches this value, heaters switch off.
Boiler Temperature HISTERESIS, (represent dead band).
Heater switch on if boiler temperature is below:
Boiler Temperature: HIGH LIMIT.
When boiler temperature reaches this value
Put 0 to disable
Boiler Temperature: LOW LIMIT.
During boiler warm-up, temperature must increase at least
otherwise
Put 0 to disable
Boiler Filling Timeout.
If filling time is longer than
Put 0 to disable
Boiler Temperature Adjust.
Boiler Priority (enable boiler wait function)
0=disabled
1=enabled
Booster Function
Overheat gap over Boiler Temperature Threshold
Boiler temperature negative differential: when the dishwasher is in
standby, boiler threshold becomes:
(Used to save energy during machine inactivity by keeping boiler
water at a lower temperature).
Tub Temperature: THRESHOLD
When tank temperature reaches this value, heater switch off.
Tub Temperature: HISTERESIS, (represent dead band).
Heater switch on if tank temperature is below:
Tank Temperature: HIGH LIMIT.
When tank temperature reaches this value
Put 0 to disable
Tank Temperature: LOW LIMIT.
During tank warm-up, temperature must increase at least
otherwise
Put 0 to disable
Tank Filling Timeout.
If filling time is longer than
Put 0 to disable
DOC. NO. 5956.65J.00
EFS - Dishwashing Systems Platform
Electrolux Professional
alarm.
warning appears.
warning.
,
alarm.
alarm.
warning appears.
warning.
,
alarm.
-
alarm appears.
°C
alarm appears.
-
-
alarm appears.
°C
alarm appears.
Factory
Unit
Min
Max
Default
[°C]
45
95
[°C]
2
10
[°C]
0
98
[°C]
0
10
[min]
0
42
[°C]
0
7
-
0
1
[°C]
0
15
[°C]
0
20
[°C]
40
85
[°C]
2
30
[°C]
0
95
[°C]
0
10
[min]
0
42
78
2
96
1
5
4
1
2
0
63
5
75
1
20
P. 11 / 174