5.4
minimum mantel clearances
WARNING
!
•
Risk of fire. Maintain all specified air space clearances to combustibles. Failure to comply with these instructions
may cause a fire or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top, vent, mantel,
front, etc.) are clearly maintained.
•
When using paint or lacquer to finish the mantel, the paint or lacquer must be heat resistant to prevent
discolouration.
An optional combustible mantel must be a minimum of 12" (30.5cm) above the top of the faceplate and not to
extend more than 2" (51mm) from the surface. See chart below for further information.
A = 8" (203mm)
B= 6" (152mm)
C= 4" (102mm)
D= 2" (51mm)
A
B
C
D
E
I
E = 12" (30.5cm)
F= 14" (35.6cm)
G= 16" (40.6cm)
H= 18" (45.7cm)
F
G
H
TOP OF
FACEPLATE
(KEYSTONE)
I = NZ7000 31 1/8" (79.1cm)
I = NZ8000 40 1/4" (102.2cm)
framing
EN
25