Minimum Mantel Clearances - Napoleon High Country 7000 Installation And Operation Manual

Low mass fireplace
Hide thumbs Also See for High Country 7000:
Table of Contents

Advertisement

5.4

minimum mantel clearances

WARNING
!
Risk of fire. Maintain all specified air space clearances to combustibles. Failure to comply with these instructions
may cause a fire or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top, vent, mantel,
front, etc.) are clearly maintained.
When using paint or lacquer to finish the mantel, the paint or lacquer must be heat resistant to prevent
discolouration.
An optional combustible mantel must be a minimum of 12" (30.5cm) above the top of the faceplate and not to
extend more than 2" (51mm) from the surface. See chart below for further information.
A = 8" (203mm)
B= 6" (152mm)
C= 4" (102mm)
D= 2" (51mm)
A
B
C
D
E
I
E = 12" (30.5cm)
F= 14" (35.6cm)
G= 16" (40.6cm)
H= 18" (45.7cm)
F
G
H
TOP OF
FACEPLATE
(KEYSTONE)
I = NZ7000 31 1/8" (79.1cm)
I = NZ8000 40 1/4" (102.2cm)
framing
EN
25
W415-1676 / C / 07.23.18