3. INSTALLATION

3.1 HOW TO INSTALL THE UNIT

1. To avoid vibration and noise, make sure the unit is installed
securely and firmly.
2. Install the unit where the sunlight does not shine directly on
the unit.
If the unit receives direct sunlight, build an awning to shade
the cabinet.
3. There should be no obstacle, like a fence, within 20" which
might restrict heat radiation from the condenser.
4. To prevent reducing performance, install the unit so that
louvers of the cabinet are not blocked.
5. Install the unit a little obliquely outward not to leak the
condensed water into the room (about 1/2" or 1/4 bubble
with level).
6. Install the unit with its bottom portion 30~60" above the floor
level.
7. Stuff the foam between the top of the unit and the wall to
prevent air and insects from getting into the room.
8. The power cord must be connected to an independent
circuit. The green wire must be grounded.
9. Connect the drain tube to the base pan hole in the rear side
if you need to drain (consult a dealer).
Plastic hose or equivalent may be connected to the drain
tube.

3.2 WINDOW REQUIREMENTS

NOTE: All supporting parts should be secured to firm wood,
masonry, or metal.
3.2.1 WINDOW REQUIREMENTS
1. This unit is designed for installation in standard
double hung windows with actual opening widths from
29" to 41".
The top and bottom window sashes must open
sufficiently to allow a clear vertical opening of 18"
from the bottom of the upper sash to the window
stool.
2. The stool offset (height between the stool and sill)
must be less than 1
1
/
".
4
FOAM
COOLED
AIR
29" to 41"
18" min
Interior wall
26" min.
(Without frame curtain)
—14—
1/4 Bubble
FENCE
AWNING
HEAT
RADIATION
About 1/2"
Over 20"
Stool
Offset
Less
than 1
Sill
Exterior
Level
1
/
"
4

Advertisement