Thank you for purchasing a Quasar product
This Quasar Room Air Conditioner has been designed to keep your room comfortably cool with maximum energy efficiency
and minimal noise.
Gracias por comprar un producto Quasar.
Este Acondicionador De Aire Quasar ha sido diseñado para mantener la habitación a una temperatura comfortable con máxima
eficiencia de energia y mínimo ruido.
CONTENTS
SAFETY PRECAUTIONS .................................................................................................................................... 2
AIR CONDITIONER INSTALLATION .................................................................................................................. 4
PART IDENTIFICATION .................................................................................................................................... 10
AIR CONDITIONER OPERATION .................................................................................................................... 12
ENERGY SAVING HINTS .................................................................................................................................. 13
CARE AND MAINTENANCE ............................................................................................................................. 14
BEFORE CALLING FOR SERVICE .................................................................................................................. 16
PRODUCT SPECIFICATIONS .......................................................................................................................... 18
CONTENIDO
PRECAUCIONES DE SEGURIDAD ................................................................................................................... 2
INSTALACIÓN DEL ACONDICIONADOR DE AIRE .......................................................................................... 4
IDENTIFICACIÓN DE LOS COMPONENTES .................................................................................................. 10
OPERACIÓN DEL ACONDICIONADOR DE AIRE ........................................................................................... 12
CONSEJOS DE AHORRAMIENTO DE ENERGÍA ........................................................................................... 13
CUIDADO Y MANTENIMIENTO ........................................................................................................................ 14
ANTES DE LLAMAR PARA MANTENIMIENTO .............................................................................................. 16
ESPECIFICACIONES DEL PRODUCTO .......................................................................................................... 18
Please read these operating instructions thoroughly before using your air conditioner and keep them for future reference.
For assistance, please call: 1-800-211-PANA (7262) or send e-mail to consumerproducts@panasonic.com or refer to
www.panasonic.com
1
F563369

Advertisement

Table of Contents
loading

Summary of Contents for Quasar HQ-2081SH

  • Page 1: Table Of Contents

    HQ-2081SH M o d e l Thank you for purchasing a Quasar product This Quasar Room Air Conditioner has been designed to keep your room comfortably cool with maximum energy efficiency and minimal noise. Gracias por comprar un producto Quasar.
  • Page 2: Safety Precautions

    PRECAUCIONES DE SEGURIDAD PRECAUCIONES DE SEGURIDAD • Please observe the following safety precautions when using your air conditioner. Failure or negligence in observing these safety precautions could cause fire, electrical shock or personal injury. • Por favor observe las siguientes precauciones de seguridad cuando use su acondicionador de aire.
  • Page 3: Operation Precautions

    OPERATION PRECAUTIONS PRECAUCIONES DE OPERACIÓN WARNING This sign warns of risk of death or serious injury. ADVERTENCIA Esta señal indica riesgo de peligro de muerte o lesiones serias. • Do not modify the length of the power cord or use an extension cord. •...
  • Page 4: Air Conditioner Installation

    AIR CONDITIONER INSTALLATION AIR CONDITIONER INSTALLATION INSTALACIÓN DEL ACONDICIONADOR DE AIRE INSTALACIÓN DEL ACONDICIONADOR DE AIRE CAUTION CUIDADO Please remove the shipping blocks fixed to the compressor and front grille before installation. Por favor remueva los tacos de envío fijados en el compresor y la rejilla frontal antes de la instalación.
  • Page 5: Select The Best Location

    NOTA: Esta unidad tambíen se puede instalar a través de la pared. En este caso, se deberán realizar trabajos de carpintería y construir una estructura en la abertura deacuerdo con los reglamentos locales. PREPARATION OF AIR CONDITIONER CHASSIS PREPARACIÓN DEL CHASIS DEL ACONDICIONADOR DE AIRE Remove the front intake grille Quite la rejilla frontal de la toma de aire Push and release.
  • Page 6 AIR CONDITIONER INSTALLATION AIR CONDITIONER INSTALLATION INSTALACIÓN DEL ACONDICIONADOR DE AIRE INSTALACIÓN DEL ACONDICIONADOR DE AIRE Remove the front grille Quite la rejilla frontal Remove the adhesive tapes from all sides of the front grille. Open the control panel cover.
  • Page 7: Cabinet Installation

    CABINET INSTALLATION INSTALACIÓN DEL CAJA Cut the “Sealing Ribbon” to the proper length, and attach it along the bottom edge of the bottom window sash. Corte la cinta de sellar del largo apropiado y colóquela a lo largo de la parte inferior de la ventana de guillotina. To prevent condensation water from dripping inside,the cabinet should be installed level or very slightly tilted to the outside.
  • Page 8 AIR CONDITIONER INSTALLATION AIR CONDITIONER INSTALLATION INSTALACIÓN DEL ACONDICIONADOR DE AIRE INSTALACIÓN DEL ACONDICIONADOR DE AIRE CHASSIS INSTALLATION INTO THE CABINET INSTALACIÓN DEL CHASIS DENTRO DE LA CAJA Slide the chassis into the cabinet Deslica el chasis dentro del caja Reinstall the chassis locking brackets and retighten the screws Reinstale las ménsulas de retención del chasis y apriete bien los tornillos...
  • Page 9: Drain Water

    COMO INSTALAR LA BANDEJA DE DRENAJE (OPCIONAL) Drain water Drenaje de agua To get the maximum cooling efficiency, this air conditioner is designed to splash the condensed water on the condenser fin. This method is called “Slinger-Up System”. If the splashing sound annoy you, you can...
  • Page 10: Part Identification

    IDENTIFICACIÓN DE LOS COMPONENTES IDENTIFICACIÓN DE LOS COMPONENTES MAIN UNIT UNIDAD PRINCIPAL Air filter (behind the front intake grille) Filtro de aire (detras de la rejilla frontal de toma de aire) Front intake grille Rejilla frontal de toma de aire Airflow Direction Vane Horizontal Airflow Direction Adjustment Side-to-Side The horizontal airflow direction vane is controlled by positioning the vane to...
  • Page 11 VENTILATION LEVER PALANCA DE VENTILACIÓN When the slide lever is in the : Cuando la palanca se encuentra deslizada en la: – “OPEN” position, the ventilation door opens to allow air, smoke or odors to be expelled from the room. –...
  • Page 12: Air Conditioner Operation

    AIR CONDITIONER OPERATION AIR CONDITIONER OPERATION OPERACIÓN DEL ACONDICIONADOR DE AIRE OPERACIÓN DEL ACONDICIONADOR DE AIRE THERMOSTAT HIGH FAN COOL HIGH COOL HIGH FAN COOL HIGH COOL THERMOSTAT NOTE : Recommended setting NOTA : Nivel recomendado * Caution : If the main control knob is turned off or changed to a fan setting from a cooling operation setting, WAIT at least 3 minutes before resetting it to a cooling operation.
  • Page 13: Energy Saving Hints

    Evite calentamiento. Proper capacity of the room The cooling capacity of the room air conditioner must match the room size for efficient and satisfactory operation. Capacidad apropiada en la habitación...
  • Page 14: Care And Maintenance

    CUIDADO Y MANTENIMIENTO CUIDADO Y MANTENIMIENTO Always turn off the air conditioner and the main power supply before unplugging the power cord to clean the unit. Switch off the power supply if the unit is not going to be used for a long period of time.
  • Page 15 INFORMACIÓN ÚTIL If the air filter becomes clogged with dust, the cooling capacity will drop, and 6% of the electricity used to operate the air conditioner will be wasted. Si el filtro de aire llega a ser atascado con el polvo, la capacidad de enfriamiento disminuirá,...
  • Page 16: Before Calling For Service

    BEFORE CALLING FOR SERVICE BEFORE CALLING FOR SERVICE ANTES DE LLAMAR PARA MANTENIMIENTO ANTES DE LLAMAR PARA MANTENIMIENTO BEFORE ANTES If the unit is noisy during operation. Si la unidad está demasiado ruidoso durante el funcionamiento. Humm… Sssssss… KACK! POSSIBLE CAUSES OF THE ABOVE PROBLEMS POSIBLES CAUSAS DE LOS PROBLEMAS ARRIBA MENCIONADOS Condition Condición...
  • Page 17 • The main power cord is not plugged in. Condition • The internal fuse has blown. Condición • The house circuit breaker has tripped. • El cable de alimentación no está enchufado. • El fusible interno se ha quemado. • El interruptor de circuitos de la casaha disparado. •...
  • Page 18: Product Specifications

    * Las especificaciones están sujetas a cambios por mejoras sin previo aviso. PRODUCT SPECIFICATIONS Phase Fase Frequency Frecuencia Voltage Voltaje Current Corriente Input Potencia Height Alto Width Ancho Depth Profundidad HQ-2081SH 7,800 Btu/h 7.800 Single Monofásico (Hz) (Amps) 11.0 (Btu/W.h) 11,0 (Pints/h) (Tinta/h) (Cf/min) (pie /min) cm (inches) 34.6 (13-...
  • Page 20: Limited Warranty

    One Panasonic Way Secaucus, New Jersey 07094 Quasar Room Air Conditioner Panasonic Consumer Electronics Company or Panasonic Sales Company (collectively referred to as “the Warrantor”) will repair this product with new or refurbished parts in case of defects in material or workmanship, free of charge, in the USA or Puerto Rico in accordance to the following (All time periods start from the date of the original purchase).