Section 15. Time Delay Switch Adjustment

15.1 Remove the blower door panel.
The Blower/Filter panel is removed using 1/4 turn
thumb screws.
1. Turn thumb screws on Blower/Filter panel.
2. Pull top of panel out, away from cabinet.
3. Lift panel up out of channel.
4. Set aside.
15.2 Time Delay Relay (TDR) Switch
Set the fan off delay setting using the Fan Delay
Relay Switch (TDR) located on the blower control
mounting plate located on the front of the blower.
Factory default delay is 90 seconds.

Section 16. Filters

16.1 Filter Considerations
A filter must be installed within the system.
A filter channel is provided in the unit, at the bot-
tom of the Blower/Filter compartment.
For customer ease of fil ter maintenance, it is
recommended that a properly sized remote filter
grill(s) be installed for units that are difficult to
access. Airflow should not exceed the maximum
rated velocity of the filter being used.
Table 16.1 Filter Sizes
Cabinet Size*
A
Filter Size
16 x 20
* Cabinet size is indicated by the 7th digit in model number.
B
C
20 x 20
22 x 20
Choke Coil
Door Switch
3/4 &1 HP
motors only
0
Fan Delay
Relay Switch
90
Filter in
air handler
cabinet
(Upflow
Application)
Transformer
35