5
Remove the valve cap (1), then
turn the gas releasing valve
clockwise, using a Philips
screwdriver (2).
Valve cap
Note
Turn the gas releasing valve clockwise until
a hissing sound comes out from the valve.
After this hissing sound stops, go to the next
step.
Xenon gas is encapsulated under high
pressure inside of the lamp. This xenon gas
is odorless and harmless. However, if you
drop the lamp or strike it without releasing
gas, the lamp may burst. This may result in
an injury.
66
6
Loosen the four screws on the
lamp unit with a Philips
screwdriver.
7
Hold the lamp unit with your
hand, and then, pushing the
lamp release lever toward the
arrow direction (toward the
right), pull the lamp unit straight
out.
Note
Hold the lamp unit tightly so that you do not
drop it, because it is heavy (approx. 2.9 kg
(6 lb 6 oz)). Dropping the lamp may result in
an injury or a breakdown of the projector.
Lamp release lever