1. Introduction
Thank you for purchasing the Toshiba industrial inverter "TOSVERT VF-A7/P7".
This manual functionally describes the light-load high-speed operation of our "TOSVERT VF-A7/P7" for
industrial use.
2. Function
This parameter provides a function of more raising the speed of motor during light load to improve the
operating efficiency of machine.
It is effectively applicable to elevators and conveyers under constant-torque loads with alternated light and
heavy loads.
3. Related parameter
List of parameters for adjusting light-load high-speed operation
Communi
Title
cation No
0330
Light-load high-speed operation
Light-load high-speed operation
0331
switching lower limit frequency
Light-load high-speed operation
0332
load waiting time
Light-load high-speed operation
0333
load detection time
Light-load high-speed operation
0334
heavy load detection time
Switching load torque current
0335
during forward run
Heavy load torque during
0336
acceleration in forward direction
Heavy load torque during fixed
0337
speed in forward direction
Switching load torque current
0338
during reverse run
Heavy load torque during
0339
acceleration in reverse direction
Heavy load torque during fixed
0340
speed in reverse direction
Automatic light-load high-speed
0341
operation frequency
0342
Light-load detection mode *2
*1 F330= 0: Disabled light-load high-speed operation
1: User interface (torque current)
2: Continuous automatic mode (torque current)
3: Continuous preset-speed mode (torque current)
4: Enabled-terminal effective automatic mode (torque current)
5: Enabled-terminal effective preset-speed mode (torque current)
6: User interface (torque)
7: Continuous automatic mode (torque)
8: Continuous preset-speed mode (torque)
9: Enabled-terminal effective automatic mode (torque)
10: Enabled-terminal effective preset-speed mode (torque)
*2 These are not before CPU version V312.
Adjustment
Function
range
0〜10 *1
30.0〜 [Hz]
0.0〜10.0 [s]
0.0〜10.0 [s]
0.0〜10.0 [s]
0〜250 [%]
0〜250 [%]
0〜250 [%]
0〜250 [%]
0〜250 [%]
0〜250 [%]
30.0〜 [Hz]
0〜255
*2
*2
Min. unit (panel/
Default
Write during
communication)
setting
running
0
Disabled
−
0.01/0.01
40.0
Enabled
0.1/0.1
1.0
Enabled
0.1/0.1
1.0
Enabled
0.1/0.1
2.0
Enabled
1
50
Enabled
1
150
Enabled
1
100
Enabled
1
50
Enabled
1
150
Enabled
1
100
Enabled
0.01/0.01
80.0
Enabled
1/1
0
Disabled
Sensorless vector/vector with sensor (●: Valid,−: Invalid)
*2
*2
*2
1
E6581172①
Vector control
V/f
Speed
Torque
Position
Constant
control
control
control
●/●
−
−
●
●/●
−
−
●
●/●
−
−
●
●/●
−
−
●
●/●
−
−
●
●/●
−
−
●
●/●
−
−
●
●/●
−
−
●
●/●
−
−
●
●/●
−
−
●
●/●
−
−
●
●/●
−
−
●
●/●
−
−
●