MAINTENANCE SPECIFICATIONS

ELECTRICAL

Item
Igntion timing:
Igntion timing (B.T.D.C.)
Advanced timing (B.T.D.C.)
Advanced type
CDI:
Pickup coil resistance/color
Source coil resistance/color
Unit model/manufacturer
Ignition coil:
Minimum spark gap
Primary winding resistance
Secondary winding resistance
Spark plug cap:
Type
Resistance
Charging system:
Type
Normal output
Stator coil resistance/color
Rectifier/regulator:
Model/manufacturer
No load regulated voltage
Capacity
Withstand voltage
Battery:
Specific gravity
Electric starter system:
Type
Starter motor
Model / manufactuter
Operation voltage
Output
Armature coil resistance
Brush overall lengt
Brush quantity
Spring force
Commutator diameter
Mica undercut (depth)
Standard
YP125E
10º at 1800 r/min
26º at 8000 r/min
Electrical type
248 ~ 372 Ω at 20 ºC/
White/Red - White/Blue
720 ~ 1,080 Ω at 20 °C/
Brown/Green - White
/MORIC
6 mm
0,19 ~ 0,27 Ω at 20 ºC
6,3 ~ 9,5 kΩ at 20 °C
Resin type
10 KΩ
A.C. magneto
14 V 170w at 5.000 r/min
0,6 ~0,9 Ω at 20 ºC/
White - White
SH640 FA / SHINDENGUEN
14,5 V
25 A
200 V
1,280
Constant mesh type
DUCATI
12 V
0,3 kW
0,0306 ~ 0,0374 Ω at 20 ºC
9,5 mm
2 pcs.
563 ~ 843 g
22 mm
1,5 mm
21
SPEC
YP180E
MORIC
Limit
•••
•••
•••
•••
•••
•••
•••
•••
•••
•••
•••
•••
•••
•••
•••
•••
•••
•••
•••
•••
•••
3,5 mm
•••
563 g
21 mm
•••