4.5

Electrical Load Analysis

Prior to installation, perform an electrical load analysis on the aircraft. Use the following values to
support the analysis:
● 28 VDC Maximum Load:
Ensure that the power input to the unit is circuit-protected.
4.6

Bonding

If bonding is required for installation and the unit is not mounted directly to the aircraft chassis, it is
recommended to attach a bonding wire from the aircraft chassis to the unit's chassis using one of the
mounting slots and appropriate hardware. The enclosure plating is yellow chromate.
4.7

Wire Shielding

Wire bundles that include I/O signals, which interconnect ALTO CSS components, should have a
shield(s) to prevent damage from high voltage surges such as lightning strikes. Examples of I/O pins
that require shielding include, but are not limited to, LED's, status outputs, switches etc. The shield
should be grounded at both ends. A single shield can be used for a large wire bundle or multiple
individual shields can be used for each wire.
4.8

FCC Regulations

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
End users must follow the specific operating instructions for satisfying RF exposure compliance. This
transmitter meets both portable and mobile limits as demonstrated in the RF Exposure Analysis. This
transmitter must not be co-located or operating in conjunction with any other antenna or transmitter
except in accordance with FCC multi-transmitter product procedures.
A V I A T I O N
30 mA
Size
Doc Type
A
PM
107840-XXXX-XXXXXPM
107840 Bluetooth Audio Interface
Drawing Number
Rev
Date
Page
3
04/11/19
19
of
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

107840-0300-00010107840-0400-00010Btt-400Btr-300

Table of Contents