Hobart KitchenAid KD-18 SERIES Service Manual page 45

Automatic dishwasher
Table of Contents

Advertisement

KDS TIMER SEQUENCE CHART
KDS SHORT WASH CYCLE PROGRAM
f'illllil
"
Time
~
;lg
p
.
:c
::;
-
-
R
.!'l"
"
0
.
I~
o
.§~
-
~~
.:;_
I~·
~13
~~~~
~~
§I~
Per
Total Elapsed
G
X
~
..,_
~
~~E~
F
c
$.o
7
~iS
~~
.
..,
Event
3:
-~ ~
1:
..
.Sit
~~=~'~
oa~~
~~
~;
0:0
PID
DV
N E
XX
X
FILL HIGH
lXXX
X
DET. DISP
.
I X X
*
X
PRE-WASH
I
X X
X
DRAIN
I
X X
s
X
FILL
HIGH
lXXX
X
DET DISP
I
X
X
X
*
X
RAPID ADVANCE
(WASH)
3XX
X
DRAIN
I
X
X
s
X
FILL HIGH
lXXX
X
RINSE
I X X
X
DRAIN
lXX
s
X
RAPID ADVANCE
3XX
X
FILL LOW R. A. DISP.
I X X
s
X
DWELL
X
XX
X
RINSE WITH HEAT
I X X
X
X
DRAIN
I X
X
s
X
DWELL
I X
X
DRAIN
SCAVENGER
I X X
s
X
AIR HEATER
&
BLOWER
15
X
XX
BLOWER
3X
X
DWELL
IX
LI<JI.PID
ADVAN E RE•ET
*
=
after door
latch
is lifted.
**
=
indicates feature is "Off' for
5
seconds,
"
On"
for
60 seconds
and "Off' for the
remaining
2.
5
seconds of the
90
second
interval. When
a
rapid advance
occurs
im-
mediately before the
S.
I.
S.,
subtract
5
seconds from the rapid advance time
and
subtract
remainder
from
the
60 seconds
to
determine
features
time.
***
=
Timer motor is
advancing
at
the
same
time
the rapid advance motor is advancing,
thereby
decreasing
the 90 second increment
by 31
seconds.
S
=
Sub
Interval Switch
f-<
Event
<I~
Iii~
Min.
Sec.
X
0
31
••o
59
I
30
I
30
..
I
30
I
30
X
0
3
..
I
30
I
30
..
X
0
3
X
..
I
30
I
30
..
I
30
..
22
30
4
30
I
30
X
•o
2
KDS PLATE WARM CYCLE PROGRAM
at
End
of
Event
Min.
Sec.
0
31
'0
3
0
4
30
6
0
7
9
0
9
3
10
30
12
0
13
30
15
0
15
3
16
30
18
0
19
30
21
0
22
30
24
0
46
30
51
0
52
30
~
Time
.
:c
.
.!'l
"
"
:3
.....
I~
o
.
.5~
"-
~
lg~~
~~
.
~
X •
~~c;;~
-"
s::""'7
0 .
X
:t
'.c
Event
i_E
E
l~
-;~c
~~~~;
~:;:o
a~~
RAPID ADVANCE••
53
X X
XX
I
RAPID ADVANCE
AIR HEATER
&
BLOWER
12 X
XX
RAPID ADVANCE
3X
REZERO
I
X
RAPID ADVANCE
2
* =
after door latch is lifted.
**
=
Pump
pauses for three 1
second
periods
in this section of rapid advance.
21g
~~
·"
·-
:E
.s,~
Per
Total
Elapsed
_
....
<
Event
at End of
'"'I<
.
Event
~
"
a~
~
Min.
Sec.
Min
.
Sec.
X
0
53
0
53
XX
0
3
0
56
X
17
4
18
0
XX
0
3
18
3
X
I
27
19
30
X
• 0
2
R
E
s
s
I
I
j
p
R
0
G
R
E
s
s
j
These
charts show which com-
ponents are energized and should
be
functioning
during
each period
of
the
program cycle.
REMEMBER:
In
addition
to the
timer,
certain other switches also
control
the
electrical power supply.
These
are:
(1)
the door
interlock
switch
(2) the over
fill control switch,
(3) the program switch and, (4)
the
various
thermostats
and
thermal
protectors_
NOTE:
On the KDS model, the timer
should be
manually advanced
ONLY
by
removing the
dial
from
the tool
(TL-7213 9) and
placing the
pointer-
like
hub
on the timer
shaft,
then
rotating
the hub
slowly clockwise
to
the desired position. The
pointer
on
the hub will indicate the
cycle phase
in which
the timer
is
operating by
pointing
to that
portion
of the dial
which is
already
printed on the
surface
of the timer_

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents