Diagnostics Tests Requiring Additional Parameters; Error Rate Test (02) Diagnostic Parameters - Sony DDS-4 Product Description Manual

Table of Contents

Advertisement

7. DIAGNOSTICS
7. 1. 7 Diagnostic Tests requiring additional parameters
The diagnostic tests which require additional information in the Parameter A, B & C bytes are:
02
Error Rate Test
43
Read Data Exerciser

7. 1. 7. 1 Error Rate Test (02) Diagnostic Parameters

This test reads or writes the number of groups defined by the Group Count. Any RAW retries, C3 ECC retries and Read/
Write hard errors encountered during the test are reported in the Error Rate Log which may then be examined to determine
tape performance.
Bit
7
Byte
0
1
2
Test Pattern
3
(MSB)
4
The Test Pattern and RND fields are only relevant if the test includes a write pass, otherwise their values are ignored.
Test Pattern: 0 - all zeros
1 - All ones
2 - Alternating ones and zeros
3 - Rotating data bytes (0,1,2,...,255)
4 - Pseudo-random data
5 - Worst case (C6h) bytes
6
5
4
Diagnostic Test Number (02h)
Loopcount
BOT
Group Count
Table 7-5: Error Rate Test Data
3
2
RND
WRT
SONY SDT-10000/SDT-11000 DDS Tape Drive
1
0
RD
NLR
(LSB)
7 - 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdt-10000Sdt-11000

Table of Contents