Table of Contents

Advertisement

3-3. System Status Screen

When the primary station is turned ON, the results of the self-diagnosis and ROM check sum value are
displayed as shown below.
If the result of the self-diagnosis is satisfactory, "OK" will be displayed at the corresponding item.
However if an error has been detected, this item will be the reversal characters.
SONY Digital Routing System DVS-V6464B
ROM CHECK SUM
RAM READ AND WRITE
REFERENCE SIGNAL
S-BUS LINK TERMINATE
REAL TIME CLOCK
STARTED
1993.02.03-22.15 STARTED BY DVS-V6464B Ver2.10 IN STATION 1
1993.02.03-22.15 S-BUS LINK DISCONNECTED TO CHANNEL B
1993.02.03-22.15 MISSING REFERENCE SIGNAL IN STATION 1
1993.02.03-22.15 POWER SUPPLY UNIT B DOWN IN STATION 1
When a message is output to the S-BUS data link, the system status screen will also show the time and
data of the event along with the message.
1990.10.12-15:42 S-BUS LINK DISCONNECTED
1990.10.27-09:28 STARTED BY BKS-R1601 Ver3.10 IN STATION 11
1990.11.03-05:31 STARTED BY BKS-R3204 Ver3.11 IN STATION 32
1991.01.14-13:51 MISSING REFERENCE SIGNAL IN STATION 1
1991.02.01-11:15 POWER SUPPLY UNIT B DOWN IN STATION 4
1991.02.04-06:11 X-POINT ERROR IN STATION 1
If some error or event happens while you open a Menu Screen or a Setting Screen, then the message will
be displayed when you open the system status screen.
The display will change to the menu screen when [Ctrl] _ [X] is pressed.
To return to the system status screen, press [Ctrl] _ [X] again.
n
When [Ctrl] _ [X] is pressed, the menu screen will be opened.
At this time, if the password is required, input the password.
ROUTING SWITCHER SYSTEM (E)
Model
ITEM
8A65
OK
OK
OK
System Status Screen
Messages of the System Status
Software version
V2.10
3-3. System Status Screen
3-3